Card reader and fire alarm pull station by an egress door, showing security solutions that work with the fire alarm

Seamless Security Solutions That Work With Fire Alarm

•

Owners rarely think of fire alarm and security as two separate projects. Instead, they see one building that must be safe, secure and easy to run. That is why more integrators now deliver security solutions side by side with fire and life safety. When it is done well, the systems work as a team. When it is not, a locked door can slow people trying to get out. Below is where fire and security meet, what the codes say about the overlap, and how to plan a project so the pieces fit, as of November 2026.

Key takeaways

  • The two trades are merging: 60% of firms in an SDM survey already sell or install fire alarm products.
  • Doors are the main overlap: codes require some electrically locked egress doors to unlock when the fire alarm activates.
  • Links belong in the design: fire alarm designs often list ties to security, as applicable.
  • Plan it as one project: shared schedules, shared drawings and one sequence of operation.

Why fire and security solutions are converging

Indeed, the line between fire and security work keeps fading. In an SDM State of the Market report from October 2025, 60% of surveyed companies said they offer, sell or install fire alarm products. Among those that did not, 19% were considering adding it within five years.

Meanwhile, the outlook stays positive. In the SDM 2026 Industry Forecast, over 40% of respondents expected fire alarm revenue to grow in 2026. So, for a security integrator, fire work is a natural next step. Likewise, fire contractors can grow into security solutions.

Where security solutions meet the fire alarm

In practice, most of the overlap comes down to doors and signals.

Delayed-egress locks

First of all, delayed-egress locks hold a door for a short time before it opens. However, the codes put limits on them. As iDigHardware explains, under the I-Codes these locks must allow immediate egress when the fire alarm or sprinkler system activates. Also, the delay is usually 15 seconds, or 30 seconds where the AHJ approves. The same article points to IBC 2021 Section 1010.2.13 and NFPA 101 Section 7.2.1.6.1.

Sensor-release doors

Similarly, some access-controlled doors unlock when a sensor sees someone walk up to them. In that case, the fire alarm often has a role. For example, Minnesota’s state fire code, as the Minnesota State Fire Marshal explains, says activation of the building fire alarm, if there is one, shall automatically unlock the door. The door then stays unlocked until the fire alarm resets.

Other interfaces

Beyond doors, projects often tie the fire alarm to elevators, HVAC and security panels. As a result, the sequence of operation must show every input and output, so each trade knows what happens in an alarm.

How to plan seamless security solutions

The best way to avoid conflicts is to plan security solutions and fire alarm together from the start. Here is a simple approach:

  1. Map every link between fire and security in one list.
  2. Write one sequence of operation that covers both.
  3. Coordinate drawings so door hardware, card readers and fire alarm relays match.
  4. Test together, with both teams present during acceptance.
  5. Train the owner’s staff on how the systems interact.

In addition, confirm the code edition and local rules for locked doors early. After all, the AHJ will check those doors closely.

What this means for contractors

Overall, security and fire work share customers, buildings and inspectors. So, the best security solutions are the ones the fire alarm already knows about. In practice:

  • Treat door hardware as a life safety item, not just a security item.
  • Put interfaces in writing before rough-in.
  • Test the whole chain, from fire alarm signal to door release.
  • Grow carefully into the other side, with the right training.

Also, keep the owner in the loop. For example, a short walk-through at handover, showing which doors release on alarm and how to reset them, can prevent false calls and frustrated staff later.

On the design side, JEM’s Fire Alarm Design work covers links to sprinkler, mechanical, elevator recall and security systems, as applicable. JEM’s site also lists security and access brands such as Lenel, Napco, Aiphone and Talkaphone.


Frequently asked questions

Do locked doors have to unlock on fire alarm?

Many do. Delayed-egress and sensor-release doors usually must release on fire alarm activation. Check the code edition and local rules.

What is the usual delay on a delayed-egress lock?

Typically 15 seconds, or 30 seconds where the AHJ approves, under the model codes cited above.

Who sets up the links between fire and security?

Ideally, both teams follow one sequence of operation. Agree on who owns what at kickoff.

This article is general information and does not replace the requirements of your jurisdiction. Confirm the applicable codes with your AHJ.


Read next: The Future of BIM in Fire and Life Safety: LOD Explained